Difficulty
Moderate
Steps
4
Time Required
1 hour
Sections
1
- Themotop Combination Central Heating and Boiler Micro Switch Maintainence
- 4 steps
Flags
2
Action Shots
Be an action hero! This guide needs images that better demonstrate how to perform specific actions.
Member-Contributed Guide
An awesome member of our community made this guide. It is not managed by iFixit staff.
BackWater Heater
Full Screen
Options
History
Save to Favorites
Download PDF
Edit
Translate
Get Shareable Link
Embed This Guide
Notify Me of Changes
Stop Notifications
Introduction
Step 1
Themotop Combination Central Heating and Boiler Micro Switch Maintainence
- PROBLEM: faulty micro switch. FIX: Disconnect power mains!!! remove the switch, check the conductivity with a multimeter.
PROBLEM: faulty micro switch. FIX: Disconnect power mains!!! remove the switch, check the conductivity with a multimeter.
1024
Step 2
- FIX: Disconnect power mains!!! remove the switch, check the conductivity with a multimeter. if the switch is faulty remove the green seal and drip some contact cleaner (alcohol) into the switch. Check the conductivity again. Let it dry upside down in a hot dry place.
FIX: Disconnect power mains!!! remove the switch, check the conductivity with a multimeter. if the switch is faulty remove the green seal and drip some contact cleaner (alcohol) into the switch. Check the conductivity again. Let it dry upside down in a hot dry place.
Step 3
- check the conductivity with a multimeter. if the switch is faulty remove the green seal and drip some alcohol into the switch. Check the conductivity again. Let it dry upside down in a hot dry place. Buy a new one if it’s still bad.
check the conductivity with a multimeter. if the switch is faulty remove the green seal and drip some alcohol into the switch. Check the conductivity again. Let it dry upside down in a hot dry place. Buy a new one if it’s still bad.
Step 4
- Put it back, reconnect mains but keep an eye on the gas flame that might turn on without the switch is being pressed (if it is so the switch is not dry inside). Say thanks to me ( atosmaximus (at) gmail.com :-)
Put it back, reconnect mains but keep an eye on the gas flame that might turn on without the switch is being pressed (if it is so the switch is not dry inside). Say thanks to me ( atosmaximus (at) gmail.com :-)
To reassemble your device, follow these instructions in reverse order.
Cancel: I did not complete this guide.
4 other people completed this guide.
Author
with 4 other contributors
atos maximus
Member since: 10/06/2013
486 Reputation
2 Guides authored
Badges: