Difficulty

Moderate

Steps

4

Time Required

                          1 hour            

Sections

1

  • Themotop Combination Central Heating and Boiler Micro Switch Maintainence
  • 4 steps

Flags

2

Action Shots

Be an action hero! This guide needs images that better demonstrate how to perform specific actions.

Member-Contributed Guide

An awesome member of our community made this guide. It is not managed by iFixit staff.

  • BackWater Heater

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

Step 1

              Themotop Combination Central Heating and Boiler Micro Switch Maintainence               
  • PROBLEM: faulty micro switch. FIX: Disconnect power mains!!! remove the switch, check the conductivity with a multimeter.

PROBLEM: faulty micro switch. FIX: Disconnect power mains!!! remove the switch, check the conductivity with a multimeter.

1024

Step 2

  • FIX: Disconnect power mains!!! remove the switch, check the conductivity with a multimeter. if the switch is faulty remove the green seal and drip some contact cleaner (alcohol) into the switch. Check the conductivity again. Let it dry upside down in a hot dry place.

FIX: Disconnect power mains!!! remove the switch, check the conductivity with a multimeter. if the switch is faulty remove the green seal and drip some contact cleaner (alcohol) into the switch. Check the conductivity again. Let it dry upside down in a hot dry place.

Step 3

  • check the conductivity with a multimeter. if the switch is faulty remove the green seal and drip some alcohol into the switch. Check the conductivity again. Let it dry upside down in a hot dry place. Buy a new one if it’s still bad.

check the conductivity with a multimeter. if the switch is faulty remove the green seal and drip some alcohol into the switch. Check the conductivity again. Let it dry upside down in a hot dry place. Buy a new one if it’s still bad.

Step 4

  • Put it back, reconnect mains but keep an eye on the gas flame that might turn on without the switch is being pressed (if it is so the switch is not dry inside). Say thanks to me ( atosmaximus (at) gmail.com :-)

Put it back, reconnect mains but keep an eye on the gas flame that might turn on without the switch is being pressed (if it is so the switch is not dry inside). Say thanks to me ( atosmaximus (at) gmail.com :-)

To reassemble your device, follow these instructions in reverse order.