Introduction
This is a fairly straight forward repair, just need to be careful of the wires going to the probe.
What you need
Step 1
Remove Screws
- Remove the stickers, heating with a hair dryer will make it easier. Then remove the bottom and take the battery out. Remove all of the screws on the back.
Remove the stickers, heating with a hair dryer will make it easier. Then remove the bottom and take the battery out. Remove all of the screws on the back.
1024
Step 2
Remove Case
- Carefully open the pen, it has a tiny wire and the power actuator lever (the white lever in the top part of the picture), can get off its pin easily.
- You can test at this point by inserting a battery and shorting the two pads circled in the second picture with your tweezers.
Carefully open the pen, it has a tiny wire and the power actuator lever (the white lever in the top part of the picture), can get off its pin easily.
You can test at this point by inserting a battery and shorting the two pads circled in the second picture with your tweezers.
Step 3
Remove Circuit Board
- Remove the two screws holding the circuit board and carefully place it in the other half. The LCD is delicate.
Remove the two screws holding the circuit board and carefully place it in the other half. The LCD is delicate.
Step 4
Remove Power Switch Contacts
- Remove the two power switch contacts. They both slide straight up, a very sharp pair of tweezers is good for this. Clean the parts with alcohol and some Deoxit if you have it and slide them back in.
Remove the two power switch contacts. They both slide straight up, a very sharp pair of tweezers is good for this. Clean the parts with alcohol and some Deoxit if you have it and slide them back in.
Step 5
Install Circuit Board
- Replace the board and make sure the battery spring makes it in to the hole on the board. There is a notch in the plastic where it should land but it can take some poking to get it seated.
Replace the board and make sure the battery spring makes it in to the hole on the board. There is a notch in the plastic where it should land but it can take some poking to get it seated.
Step 6
Lubricate the O-Rings
- Carefully lift the probe, the wire is wrapped around the hub inside. Remove the grease from both sides and apply a thin coating of Super Lube O-Ring lubricant. When putting the probe back down make sure the wire is not pinched and wraps around the hub like it was.
- Verify the wire is seated properly by opening the probe while holding it down and make sure the wire is not pulled. It should be routed behind the screw post as shown.
- Put the two halves back together making sure to not pinch the wire.
Carefully lift the probe, the wire is wrapped around the hub inside. Remove the grease from both sides and apply a thin coating of Super Lube O-Ring lubricant. When putting the probe back down make sure the wire is not pinched and wraps around the hub like it was.
Verify the wire is seated properly by opening the probe while holding it down and make sure the wire is not pulled. It should be routed behind the screw post as shown.
Put the two halves back together making sure to not pinch the wire.