What you need
Step 1
Pressure Regulator Chamber Gasket
- Using a 4mm Allen wrench, remove the 4 Allen screws, 44mm in length, from the yellow cap on the back of the brad nailer.
Using a 4mm Allen wrench, remove the 4 Allen screws, 44mm in length, from the yellow cap on the back of the brad nailer.
1024
Step 2
- Remove the yellow cap to reveal the gasket.
- Keep the nailer upright so the piston does not fall out. If the piston falls out, simply put it back in place.
Remove the yellow cap to reveal the gasket.
Keep the nailer upright so the piston does not fall out. If the piston falls out, simply put it back in place.
Step 3
- Remove the faulty gasket and replace it with a new gasket.
Remove the faulty gasket and replace it with a new gasket.
To reassemble your device, follow these instructions in reverse order.